FIRE

        NAC POWER EXTENDERS
       AL602ULADA                  AL802ULADA                  AL1002ULADA
       • UL Listed in the U .S . for Fire, UL 864  • UL Listed in the U .S . for Fire, UL 864  • UL Listed in the U .S . for Fire, UL 864
         9th edition, CSFM and FM Approved .    9th edition, CSFM and FM Approved .    9th edition, CSFM and FM Approved .
       • 6 .5 amp @ 24VDC .        • 8 amp @ 24VDC .           • 10 amp @ 24VDC .
       • Two (2) Class A or four (4) Class B      • Two (2) Class A or four (4) Class B      • Two (2) Class A or four (4) Class B
         outputs with built-in sync  protocols .    outputs with built-in sync protocols .    outputs with built-in sync protocols .
       • Fits two (2) 12VDC/12AH batteries .  • Two (2) NC dry contact trigger inputs .  • Two (2) NC dry contact trigger inputs .
       Enclosure dimensions:       • Fits two (2) 12VDC/12AH batteries .  • Fits two (2) 12VDC/12AH batteries .
       15 .5”H x 12 .23”W x 4 .5”D  Enclosure dimensions:      Enclosure dimensions:
                                   15 .5”H x 12 .23”W x 4 .5”D    15 .5”H x 12 .23”W x 4 .5”D
        Features:
        •  Two (2) Class A or two (2) Class B FACP inputs .  •  Temporal Code 3, Steady Mode, Input to Output Follower Mode
   124  •  Two (2) NC dry contact trigger inputs .    (maintains synchronization of notification appliance circuits) .
        •  Two (2) Class B outputs may be paralleled for more  •  Compatible with 12VDC or 24VDC fire panels .
          power on an indicating circuit .       •  Common trouble inputs and outputs .  AL602ULADA
        •  One (1) aux . power output @ 1 amp supply current   •  Ground fault detection .
          (with battery back up) .               •  AC fail, low battery
        •  Signal circuit trouble memory - facilitates quickly locating intermittent    and battery presence
          system trouble and eliminates costly and unnecessary service calls .    supervision .
          LEDs indicate a prior fault (short, open, ground) has occurred on  •  115VAC 60Hz . input .
          one or more signaling circuit outputs .  •  Includes cam lock
        •  2-wire horn/strobe sync mode allows audible notification     and battery leads .
          appliances (horns) to be silenced while visual notification
          appliances (strobes) continue to operate .
        •  Built-in Cooper®, Gentex®, Potter® and System Sensor® sync protocols .
                                   All above models are available in larger enclosure.   (Batteries optional - order separately)
                                   Add suffix “J” to model number (i.e. AL802ULADAJ).