Page 96 - Altronix Product Guide
P. 96
ACCESS
POE DRIVEN ACCESS POWER CONTROLLER
Tango8A(CB)
ACMS8/ACMS8CB Access Power Controller: Any of the eight (8) power outputs are selectable for
Inputs: 12VDC or 24VDC .
12VDC and 24VDC from Tango1B, factory wired . Individual outputs may be set to OFF position for servicing .
Current Consumption: 0 .6A @ 12V, 0 .3A @ 24V with all Output Ratings:
relays energized Fuses are rated 2 .5A each, PTCs are rated at 2A .
Main Fuse Rating: 15/32A . Fire Alarm Disconnect:
Trigger Inputs: Supervised Latching or non-latching, individually
Eight (8) individually controlled trigger inputs: selectable for any or all of the eight (8) outputs .
a) Normally open (NO) inputs . EOL 10K Resistor .
b) Normally closed (NC) inputs . Indicators (LED):
c) Open collector sink inputs . Red LEDs: Outputs are triggered (relays energized) .
96 d) Wet Input (5VDC - 24VDC) with 10K resistor . Blue LED s: FACP disconnect is triggered .
e) Any combination of the above . Voltage LEDs: 12VDC (Green), 24VDC (Red) .
Outputs:
Tango8A: Eight (8) Fuse protected outputs rated @ 2 .5A per Tango8AP(CB) includes ACMS8(CB)
output, non power-limited . Total output 20A max . PDS8/PDS8CB Power Distribution Module:
Tango8ACB: Eight (8) PTC protected outputs rated @ 2A per Inputs:
output, Class 2 power-limited . Total output 16A max . 12VDC and 24VDC from Tango1B, factory wired .
Do not exceed the individual power supply ratings . Main Fuse Rating 10A/32V .
Eight (8) selectable 12VDC or 24VDC independently controlled Outputs:
outputs or eight (8) indepently controlled Form “C” relay outputs: Tango8AP: Fuse protected outputs rated @ 3A per output,
a) Fail-Safe and/or Fail-Secure power outputs . non power-limited . Total output 20A max .
b) Form “C” Relays . 28VAC or VDC @ 2 .5A Rated . Tango8APCB: PTC protected outputs rated @ 2A per output,
c) Auxiliary power outputs (unswitched) . Class 2 power-limited . Total output 16A max .
d) Any combination of the above .
888.258.7669
®