Page 41 - Altronix Product Guide
P. 41

ACCESS
                                     COMPACT, COST EFFECTIVE
                                 FIT
                                     ACCESS POWER CONTROLLERS
         Features:
         ACM8 Access Power Controller:  FIT       PD8UL Power Distribution Module:
         •  Eight (8) Access Control System trigger inputs .  •  Eight (8) fuse protected outputs .
         •  Input options:                        PD16W Power Distribution Module:
           a)  Eight (8) normally open [NO] inputs .  •  Sixteen (16) fuse protected outputs .
           b)  Eight (8) open collector inputs .  PDS8UL Dual Input/Output Power Distribution Module:
           c)  Any combination of the above .     • Same features as PD8UL with:
         •  Eight (8) independently controlled fuse protected outputs .  • Eight (8) fuse protected power outputs are individually selectable
         •  Output options (models with fuse protected outputs):    to follow power input 1 or input 2 .
           a)  Eight (8) Fail-Safe and/or Fail-Secure power outputs .  eFlow Power Supply/Charger:
            b)  Eight (8) form “C” 5 amp rated relay outputs .  •  120VAC 60Hz . input .
           c)  Any combination of the above .
         •  Output options (models with PTC protected outputs):  •  Additional aux . power-limited output(s) rated @ 1 amp (unswitched) .  41
                                                  •  Supervised Fire Alarm disconnect .
           a)  Eight (8) Fail-Safe and/or Fail-Secure power outputs .
         •  Eight (8) auxiliary power outputs (unswitched)  .  •  Over voltage protection - guards against equipment damage
                                                  •  Built-in charger for sealed lead acid or gel type batteries .
         •  ACM8 main fuse is rated @ 10 amp .
         •  Red LEDs indicate outputs are triggered (relays energized) .  •  AC fail supervision, battery fail & presence supervision .
                                                  •  Automatic switch over to stand-by battery when AC fails .
         •  Fire Alarm disconnect (latching or non-latching) is individually selectable
           for any or all of the Eight (8) outputs .    Transfer to stand-by battery power is instantaneous with no interruption .
                                                  •  Low battery cutoff - prevents batteries from discharge .
         •  Fire Alarm disconnect input options:
           a)  Normally open [NO] or normally closed [NC] dry contact input .  •  Green AC Power LED indicates 120VAC present .
                                                  •  AC input and DC output LED indicators .
           b)  Polarity reversal input from FACP signaling circuit .  •  Short circuit and overload protection .
         ACMS8 Dual Input/Output Access Power Controller:  •  Includes cam lock and battery leads .
         • Same features as ACM8 with:            Enclosure Dimensions: 20 .5”H x 16 .5”W x 6 .25”D
         • Eight (8) fuse protected power outputs are individually selectable
           to follow power input 1 or input 2 .