         ACCESS POWER CONTROLLERS
                                          Eight (8) Output
        ACM8                                      ACM8CB
        • UL Listed Sub-Assembly in the U .S . and Canada for Access Control,   • UL Listed Sub-Assembly in the U .S . and Canada for Access Control,
          UL Listed Sub-Assembly in Canada for Burglar Alarms .    UL Listed Sub-Assembly in Canada for Burglar Alarms .
        • Eight (8) fuse protected outputs .      • Eight (8) PTC protected outputs .
        Board dimensions: 4 .5”L x 8”W x 1 .25”H  Board dimensions: 4 .5”L x 8”W x 1 .25”H
        ACM8E                                     ACM8CBE
        • UL Listed in the U .S . and Canada for Access Control,   • UL Listed in the U .S . and Canada for Access Control,
          UL Listed in Canada for Burglar . CSFM Approved .    UL Listed in Canada for Burglar . CSFM Approved .
        • Eight (8) fuse protected outputs .      • Eight (8) Class 2 Rated PTC protected power-limited outputs .
        Enclosure dimensions: 15 .5”H x 12 .23”W x 4 .5”D    Enclosure dimensions: 15 .5”H x 12 .23”W x 4 .5”D
         Features:
         •  12 to 24 volt AC or DC operation (setting not required) .  •  Output options (ACM8CB and ACM8CBE):  29
         •  Power supply input options:             a)  Eight (8) Fail-Safe and/or Fail-Secure power outputs .
           a)  One (1) common power input (board and lock power) .  •  Eight (8) auxiliary power   ACM8
           b)  Two (2) isolated power inputs (one (1) for board power         outputs (unswitched) .
             and one (1) for lock/hardware power) .  •  Red LEDs indicate outputs
         •  Eight (8) Access Control System trigger inputs .    are triggered (relays energized) .
         •  Input options:                        •  Fire Alarm disconnect (latching or
           a)  Eight (8) normally open [NO] inputs .    non-latching) is individually selectable
           b)  Eight (8) open collector inputs .    for any or all of the eight (8) outputs .
           c)  Any combination of the above .     •  Fire Alarm disconnect input options:
         •  Eight (8) independently controlled fuse protected outputs .    a) Normally open [NO] or normally closed [NC] dry contact input .
         •  Output options (ACM8 and ACM8E):        b) Polarity reversal input from FACP signaling circuit .
           a)  Eight (8) Fail-Safe and/or Fail-Secure power outputs .  •  Alarm output relay indicates that FACP input is triggered .
           b)  Eight (8) form “C” 5 amp rated relay outputs   •  Green LED indicates FACP disconnect is triggered .
           c)  Any combination of the above .     *  Units will operate from 12 volts to 24 volts AC or DC with a total
                                                    load of 10 amp max. Output voltage is equal to the input voltage.